Set up the clash matrix
The first two steps of a clash check decide what is checked: the (which objects) and the (which of them against which, how deep an overlap must be, which storeys and what to ignore). Grouping and severity come next; see Grouping and severity.
What is the clash matrix?
A table with the same rows and columns: by default every model, and inside it every object type. Each cell is one pair, for example HVAC IfcFlowSegment against Structure IfcBeam. SiloLink tests only the pairs whose cell is checked, so the matrix is where you leave out what does not matter, such as doors against furniture.
1. Choose the detection source
Every object in the detection source is checked against every other one, as the clash matrix allows.
- Models (1): tick the models to check. Ticking a folder ticks all its models; Select all ticks every model.
- Version (2): each model is checked at its latest version unless you pick another one.
- Model tree (3): open a model with its arrow to tick single storeys, IFC classes or objects, or search by name, type or GUID.
To check only some objects, such as the load-bearing elements, use views; see Clash detection with views.
2. Open the matrix
Click Configure matrix. The matrix opens on its own page; the line at the top sums it up, for example 4,713 objects, 3 disciplines, 30 object types, 300 enabled pairs.
- Levels (1): what the rows and columns are. See the next section.
- Pairs (2): checked pairs are blue, unchecked ones white. Gray pairs are left out by a filter.
- Tools (3): clear the matrix, zoom out and zoom in.
- Settings (4): tolerances, storeys and filters, then OK.
Every change shows at once. OK keeps your changes for this check; Cancel undoes everything you changed since you opened the matrix. Save as my default makes the current matrix the starting point of your next clash checks.
3. Choose what the rows and columns are
The rows and columns have up to two levels:
- Level 1 (required): the outer grouping. Model by default.
- Level 2 (optional): the inner grouping inside each Level 1 value. Object type, the IFC class, by default. Remove it with × for a coarser matrix, or add it again with + Level 2.
Click a level to choose its source (1): Model, Discipline or Object type, or any property the models carry, listed by property set (2) with the share of objects that have it. Search to find one quickly.
A property as a level lets you check by responsibility, for example Level 1 a DIN 276 cost group and Level 2 the object type: each row is then one cost group's walls, slabs or ducts.
Objects without a value at a level are not in the matrix, so they are not checked. SiloLink warns you when few objects have a value, when a property has a different value for almost every object, or when it makes more rows than a matrix can show.
4. Choose the pairs
- Click a cell to turn one pair on or off.
- Click a row's name, or a Level 1 heading such as Architecture, to turn all its pairs off, and click again to turn them on.
- Clear matrix turns every pair off. From then on only what you click is checked, also when a later model version brings new object types.
New levels and Restore defaults start again from every pair checked.
5. Understand tolerances
Click the info button next to General tolerances (1) to see how they work (2). SiloLink measures only the overlap of two objects: L is its longer horizontal side, W its shorter horizontal side and H its height.
- Separate: a clash only when W exceeds the width tolerance and H exceeds the height tolerance. The more lenient mode.
- Uniform: a clash when W or H exceeds one tolerance. Stricter.
Both start at 10 mm.
6. Limit the storeys
Open Levels (1) in the settings and tick the storeys to check (2). Each storey shows how many objects it holds; objects without a storey are listed as Unknown.
7. Choose what to ignore
The Filters (1) leave out clashes that are rarely real problems:
| Filter | Default | Leaves out |
|---|---|---|
| Ignore clashes within each model | Off | Clashes between two objects of the same model. The name follows Level 1, for example within each discipline. |
| Ignore same system | On | Clashes between parts of one MEP system, such as a pipe and its own fitting. |
| Ignore IfcSpace, IfcOpeningElement, IfcCovering, IfcFurniture, IfcVirtualElement | On | Rooms, openings, coverings, furniture and virtual elements. |
| Ignore IfcBuildingElementProxy | Off | Generic proxy objects, which some tools export for anything they cannot classify. |
Restore defaults (2) brings back the standard matrix, Model and Object type, with these defaults. Click OK (3) to keep your changes and go back to the setup, or Cancel to undo them.